TamlynWrap® Rainscreen 10.1
TamlynWrap® Rainscreen 10.1 - 5' x 50' - 250 sqft/roll is backordered and will ship as soon as it is back in stock.
Safe & Secure Payments
Product Description
TamlynWrap Rainscreen 10.1 — 3-in-1 Water Resistive Barrier with 10.1mm Drainage Gap
| ITEM ID | TWR101 |
|---|---|
| WIDTH | 5 ft |
| LENGTH | 50 ft |
| COVERAGE | 250 sf |
| ROLL WEIGHT | 22 lbs |
| THICKNESS | 10.5 mm |
| DRAINAGE GAP | 10.1 mm |
| UV RATING | Maximum 120 days |
| WARRANTY | 15 year limited |
The TamlynWrap Rainscreen 10.1 (TWR101) is a 3-in-1 Water Resistive Barrier system engineered to simultaneously enhance drainage efficiency, improve drying proficiency, and accelerate construction expediency. Each roll covers 250 square feet at 5 ft wide by 50 ft long, and the product is designed for use over sheathing substrates including OSB, coated OSB, and plywood. It is compatible with a wide range of cladding types including Stucco, Fiber Cement Board, Stone, and Metal Panels, making it a versatile solution for commercial and residential wall assemblies.
Unlike conventional house wraps or flat WRBs, the TamlynWrap Rainscreen 10.1 creates an uncompressible 10.1mm (over 3/8 inch) air cavity between the cladding and sheathing using its thick filament structure. This cavity allows both the sheathing and the back of the cladding to dry significantly faster than in a traditional assembly, reducing the risk of moisture-related damage, mold, and structural deterioration over the building's service life.
Key Features & Benefits
3-in-1 Water Management System
This single product combines a water resistive barrier, a drainage plane, and a drying plane into one installation step. Contractors eliminate the need for separate furring strip installation, reducing both labor time and material cost on the jobsite.
10.1mm Uncompressible Filament Drainage Gap
The 10.1mm thick filament matrix is uncompressible under cladding loads, maintaining a consistent air cavity that exceeds 3/8 inches throughout the life of the assembly. This gap ensures continuous drainage and ventilation behind the cladding, critical for long-term moisture management performance.
Acts as a Furring Strip
Because the filament is uncompressible, the product functions as an integrated furring strip. This eliminates the need to install separate wood or metal furring, reducing installation cost, scheduling time, and potential liability associated with furring strip attachment failures.
Accelerated Sheathing and Cladding Drying
The open air cavity allows both the sheathing substrate (OSB, plywood) and the back face of the cladding to dry rapidly after moisture infiltration. Faster drying extends the service life of structural sheathing and reduces the incidence of moisture-driven cladding failures.
Broad Cladding Compatibility
Engineered to work behind stucco, fiber cement board, stone, and metal panel systems, the TWR101 is adaptable to nearly any exterior cladding type encountered in commercial or residential construction. This versatility reduces the number of WRB SKUs a contractor needs to stock.
15-Year Product Limited Warranty
The TamlynWrap Rainscreen carries a 15-year product limited warranty when installed per Tamlyn's published installation instructions. A 25-year product and labor warranty is available when installed as a complete Tamlyn Water Management System with qualifying accessory products and project registration.
Common Applications
Stucco Cladding Systems
The 10.1mm drainage gap provides the required air space behind stucco to allow moisture that penetrates the cladding to drain and dry, addressing one of the most common failure modes in stucco wall assemblies.
Fiber Cement Board Siding
Fiber cement siding manufacturers often require a drainage gap behind their products. The TWR101 provides this gap while serving as the WRB, simplifying the wall assembly and meeting manufacturer installation requirements.
Stone Veneer Systems
Stone veneers are highly susceptible to moisture trapping at the sheathing interface. The drainage cavity created by the TWR101 allows moisture to escape rather than accumulate, protecting both the sheathing and the stone setting materials.
Metal Panel Facades
Metal panel systems can experience condensation at the back face. The ventilated cavity behind the panels allows this moisture to evaporate rather than contact the sheathing, preventing corrosion of fasteners and deterioration of substrate materials.
Commercial and Residential New Construction
The product is suited for new wall construction across building types where code-compliant water management and long-term moisture durability are required, including mid-rise commercial, multifamily, and single-family residential projects.
Retrofit and Re-cladding Projects
When re-cladding an existing structure, the TWR101 can be installed over existing sheathing to upgrade the wall assembly's drainage and drying capacity without requiring structural changes to the wall framing.
Compatible Materials
- OSB (Oriented Strand Board) sheathing
- Coated OSB sheathing
- Plywood sheathing
- Stucco cladding systems
- Fiber Cement Board siding
- Stone veneer cladding
- Metal panel facade systems
- XtremeFlashing™ Tape (Tamlyn accessory)
- XtremeSealant™ / Tamlyn BrunnoSeal® (Tamlyn accessory)
- XtremeSeam™ Tape (Tamlyn accessory)
- XtremeCorners™ or bowtie methods (Tamlyn accessory)
Product Documents
Application Instructions
Surface Preparation
- Ensure the sheathing substrate (OSB, coated OSB, or plywood) is properly fastened, structurally sound, and free of debris.
- All penetrations, window and door rough openings, and transitions should be pre-flashed with XtremeFlashing™ Tape and XtremeSealant™ / BrunnoSeal® per Tamlyn's flashing details prior to WRB installation.
Installation
- Install TamlynWrap Rainscreen 10.1 starting at the base of the wall, working horizontally and lapping upper courses over lower courses per standard WRB installation practice.
- Fasten using cap fasteners throughout — cap fasteners are required per the warranty terms.
- Seams should be taped with XtremeSeam™ Tape to maintain WRB continuity.
- Use XtremeCorners™ or approved bowtie methods at corners.
- Limit UV exposure to a maximum of 120 days before covering with cladding.
Cladding Installation
- Install cladding (stucco, fiber cement, stone, or metal panels) directly over the TamlynWrap Rainscreen 10.1 filament surface — the uncompressible filament acts as the furring strip, maintaining the 10.1mm drainage gap without additional framing.
- Follow applicable building codes and cladding manufacturer installation requirements for fastening schedules and joint treatment.
Warranty Registration
- For the 25-year product and labor warranty, complete project registration with Tamlyn by submitting the Warranty Registration Form to [email protected] or fax to 281-499-8948.
- Confirm all required Tamlyn accessory products were used in the installation prior to submitting registration.
Technical Specifications
| Specification | Details |
|---|---|
| Item ID | TWR101 |
| Width | 5 ft |
| Length | 50 ft |
| Coverage | 250 SF per roll |
| Roll Weight | 22 lbs |
| Thickness | 10.5 mm |
| Drainage Gap | 10.1 mm (over 3/8 inch) |
| UV Rating | Maximum 120 days |
| Product Warranty | 15-year product limited warranty |
| System Warranty (with accessories + registration) | 25-year product and labor limited warranty |
| Fastener Requirement | Cap fasteners required throughout |
Frequently Asked Questions
Q: Does the TamlynWrap Rainscreen 10.1 eliminate the need for separate furring strips?
A: Yes. The 10.1mm uncompressible filament acts as an integrated furring strip, maintaining the required drainage gap behind cladding without the need to install separate wood or metal furring strips, reducing labor and material costs.
Q: What cladding types can be installed over the TWR101?
A: The product is compatible with stucco, fiber cement board, stone veneer, and metal panel systems. It is suitable for any cladding type that benefits from a vented drainage cavity behind the cladding face.
Q: Is project registration required for warranty coverage?
A: Project registration is required to obtain the 25-year product and labor limited warranty. The 15-year product-only warranty does not require registration but does require installation per Tamlyn's published instructions using compatible Tamlyn accessory products.
Q: What are the UV exposure limits for this product?
A: The TamlynWrap Rainscreen 10.1 must be covered with cladding within a maximum of 120 days of installation. Exceeding the UV exposure limit will void the warranty per Tamlyn's installation guidelines.
Q: What fasteners are required for installation?
A: Cap fasteners are required throughout the installation. Standard staples or nails without caps are not acceptable under the warranty terms.
Q: Can this product be used on commercial projects?
A: Yes. The TamlynWrap Rainscreen 10.1 is suitable for both commercial and residential wall assemblies. For commercial projects requiring the 25-year system warranty, all specified Tamlyn accessory products must be used and the project must be registered with Tamlyn prior to or during installation.


